因在linux 系统中无法查看系统磁盘的raid级别,也无法得知raid状态,需要安装额外的包来监控,因是dell服务器,就在dell网站中下载并安装
1、下载链接:驱动程序和下载 | Dell 中国
https://www.dell.com/support/home/zh-cn?app=drivers选择产品型号并选择驱动类型

下载的包如下图,下载后上传到/opt目录下

在主机安装并使用
root@hydb opt]# rpm -ivh perccli-1.17.10-1.noarch.rpm
 Verifying...                          ################################# [100%]
 Preparing...                          ################################# [100%]
 Updating / installing...
    1:perccli-1.17.10-1                ################################# [100%]
 [root@hydb opt]#
[root@hydb perccli]# ln -s /opt/MegaRAID/perccli/perccli64 /bin/perccli
 [root@hydb ~]#
[root@hydb ~]#  perccli /c0/eall/sall show
 Controller = 0
 Status = Success
 Description = Show Drive Information Succeeded.
 Drive Information :
 =================
-------------------------------------------------------------------------
 EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
 -------------------------------------------------------------------------
 64:0      2 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
 64:1      0 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
 64:2      1 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
 64:3      4 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
 64:4      3 GHS    -   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
 -------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
 DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
 UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
 Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
 SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
 UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
 CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
 [root@hydb ~]# perccli /c0/vall show
 Controller = 0
 Status = Success
 Description = None
 Virtual Drives :
 ==============
-----------------------------------------------------------------------
 DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name         
 -----------------------------------------------------------------------
 1/238 RAID1 Optl  RW     No      RWBD  -   OFF   1.818 TB loccalbackup
 0/239 RAID1 Optl  RW     Yes     RWBD  -   OFF 446.625 GB              
 -----------------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
 Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|B=Blocked|Consist=Consistent|
 R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
 AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
 Check Consistency
 [root@hydb ~]# perccli show ctrlcount
 Status Code = 0
 Status = Success
 Description = None
Controller Count = 1
查看控制器的信息
**perccli show ctrlcount 查看有几个控制器即几个raid卡 **
perccli show 显示raid卡信息
 [root@hydb ~]# perccli show
 Status Code = 0
 Status = Success
 Description = None
Number of Controllers = 1
 Host Name = dbdg
 Operating System  = Linux5.15.0-101.103.2.1.el8uek.x86_64
System Overview :
 ===============
---------------------------------------------------------------------------
 Ctl Model           Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
 ---------------------------------------------------------------------------
   0 PERCH750Adapter     8   5   2     0   2     0 Opt On  -  N      0 Opt  
 ---------------------------------------------------------------------------
Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
 PDs=Physical drives|DNOpt=DG NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
 Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
 sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Hot Spare
 Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit
 Hlth=Health|Safe=Safe-mode boot
 [root@hydb ~]# perccli /c0 show
 Generating detailed summary of the adapter, it may take a while to complete.
Controller = 0
 Status = Success
 Description = None
Vendor Id = 0x1000
 Device Id = 0x10E2
 SubVendor Id = 0x1028
 SubDevice Id = 0x2176
 Host Interface = PCI-E
 Device Interface = SATA-3G
 Bus Number = 134
 Device Number = 0
 Function Number = 0
 Drive Groups = 2
TOPOLOGY :
 ========
--------------------------------------------------------------------------
 DG Arr Row EID:Slot DID Type  State BT       Size PDC  PI SED DS3  FSpace
 --------------------------------------------------------------------------
  0 -   -   -        -   RAID1 Optl  N  446.625 GB dflt N  N   dflt N      
  0 0   -   -        -   RAID1 Optl  N  446.625 GB dflt N  N   dflt N      
  0 0   0   64:0     2   DRIVE Onln  N  446.625 GB dflt N  N   dflt -      
  0 0   1   64:1     0   DRIVE Onln  N  446.625 GB dflt N  N   dflt -      
  1 -   -   -        -   RAID1 Optl  Y    1.818 TB dflt N  N   dflt N      
  1 0   -   -        -   RAID1 Optl  Y    1.818 TB dflt N  N   dflt N      
  1 0   0   64:2     1   DRIVE Onln  N    1.818 TB dflt N  N   dflt -      
  1 0   1   64:3     4   DRIVE Onln  N    1.818 TB dflt N  N   dflt -      
 --------------------------------------------------------------------------
DG=Disk Group Index|Arr=Array Index|Row=Row Index|EID=Enclosure Device ID
 DID=Device ID|Type=Drive Type|Onln=Online|Rbld=Rebuild|Dgrd=Degraded
 Pdgd=Partially degraded|Offln=Offline|BT=Background Task Active
 PDC=PD Cache|PI=Protection Info|SED=Self Encrypting Drive|Frgn=Foreign
 DS3=Dimmer Switch 3|dflt=Default|Msng=Missing|FSpace=Free Space Present
Virtual Drives = 2
VD LIST :
 =======
-----------------------------------------------------------------------
 DG/VD TYPE  State Access Consist Cache Cac sCC       Size Name         
 -----------------------------------------------------------------------
 0/239 RAID1 Optl  RW     Yes     RWBD  -   OFF 446.625 GB              
 1/238 RAID1 Optl  RW     No      RWBD  -   OFF   1.818 TB loccalbackup
 -----------------------------------------------------------------------
Cac=CacheCade|Rec=Recovery|OfLn=OffLine|Pdgd=Partially Degraded|dgrd=Degraded
 Optl=Optimal|RO=Read Only|RW=Read Write|HD=Hidden|B=Blocked|Consist=Consistent|
 R=Read Ahead Always|NR=No Read Ahead|WB=WriteBack|
 AWB=Always WriteBack|WT=WriteThrough|C=Cached IO|D=Direct IO|sCC=Scheduled
 Check Consistency
Physical Drives = 5
PD LIST :
 =======
-------------------------------------------------------------------------
 EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
 -------------------------------------------------------------------------
 64:0      2 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
 64:1      0 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
 64:2      1 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
 64:3      4 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
 64:4      3 GHS    -   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
 -------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
 DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
 UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
 Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
 SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
 UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
 CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
 BBU_Info :
 ========
-------------------------------------------------------------------
 Model State   RetentionTime Temp Mode MfgDate Next Learn           
 -------------------------------------------------------------------
 BBU   Optimal 0 hour(s)     31C  -    0/00/00 2024/02/20  03:22:19
 -------------------------------------------------------------------
 [root@hydb ~]#
 看磁盘的Device id、Slot No. 以及DriveGroup
 [root@hydb ~]#  perccli /c0/eall/sall show
 Controller = 0
 Status = Success
 Description = Show Drive Information Succeeded.
Drive Information :
 =================
-------------------------------------------------------------------------
 EID:Slt DID State DG       Size Intf Med SED PI SeSz Model            Sp
 -------------------------------------------------------------------------
 64:0      2 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
 64:1      0 Onln   0 446.625 GB SATA SSD N   N  512B HFS480G4I5X569N  U  
 64:2      1 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
 64:3      4 Onln   1   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
 64:4      3 GHS    -   1.818 TB SAS  HDD N   N  512B ST4000NM026A     U  
 -------------------------------------------------------------------------
EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
 DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
 UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
 Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
 SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
 UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
 CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded
 [root@hydb ~]#
 [root@hydb ~]# lsscsi
 [0:3:110:0]  disk    DELL     PERC H750 Adp    5.16  /dev/sda
 [0:3:111:0]  disk    DELL     PERC H750 Adp    5.16  /dev/sdb
 [root@hydb ~]#